Skip to main content

Chris Engelbert Chris Engelbert

vSAN Sizer and ReadyNodes After the Exit: How to Size OpenShift Virtualization Storage Yourself

Oct 30, 2026  |  12 min read

vSAN Sizer and ReadyNodes After the Exit: How to Size OpenShift Virtualization Storage Yourself

The vSAN Sizer and the vSAN ReadyNode program cover only vSAN, so after a VMware® exit you work out their answers yourself for Red Hat® OpenShift® Virtualization or KubeVirt. Three answers matter: raw capacity after protection, the CPU and memory reserved on each node, and whether storage grows when you add compute.

The destination figures come from the simplyblock 26.3 documentation and the OKD 4.22 virtualization requirements, and the vSAN figures from Broadcom and VMware. OKD is the community distribution of OpenShift. Check the Red Hat documentation for your OpenShift version before you order.

What the vSAN Sizer and ReadyNode profiles decided for you

The vSAN Sizer turned a workload description into protected capacity and vSAN memory per node, and a ReadyNode turned that into a server you could order. Broadcom now hosts the tool as the vSAN ReadyNode Sizer.

A 2022 VMware blog on refreshing vSAN clusters describes the input side. The Sizer expected capacity “as the VM would see it”, which some teams imported from Live Optics, OneIQ or RVTools. It then added the capacity needed for the resilience level you chose. The same blog warns that vSAN’s own capacity view splits usage into Primary Data and replica data, and that the Sizer wants the Primary Data values from the Usage Breakdown. Take that figure for your new worksheet too: the total already contains vSAN’s replicas, and adding erasure coding overhead on top would count protection twice. According to Broadcom KB 314302, the Sizer also showed vSAN memory consumption per node for the workload you entered.

The ReadyNode side defined the server. Broadcom KB 326717 describes vSAN ESA ReadyNodes as x86 servers that are pre-configured, tested and certified, with the required CPU, memory, network and NVMe devices. Drive changes stay within the drive models of the ReadyNode bill of materials and within the same server vendor. vSAN ESA vs OSA hardware requirements compares what each architecture needs.

A November 2025 VMware Cloud Foundation blog lists the current profile minimums. ReadyNodes for vSAN HCI clusters and for vSAN storage clusters start at 16 cores and 128 GB of RAM per host. vSAN uses more memory for each storage device it claims, so more devices need more RAM. The same post highly recommends 25 Gb or faster networking for greenfield builds.

Where each sizing job lands after the exit

Table 1 maps each job the Sizer and the ReadyNode list did to OpenShift Virtualization with simplyblock as the storage layer, which spreads erasure-coded data across its storage nodes. You own every row except certification.

Table 1: where each vSAN sizing job lands.

vSAN constructWhat it didWhere it lands
Sizer workload profileTook capacity as the VM sees itThe Primary Data export, in your own worksheet
Sizer resilience settingAdded protection capacityThe erasure coding scheme you choose when you deploy the simplyblock cluster
Sizer memory per nodeShowed vSAN memory use per hostThe storage node memory formula
ReadyNode CPU and memory floorSet minimum cores and RAM per hostStorage vCPUs and memory per storage node, plus OpenShift Virtualization overhead, on top of the VMs’ own CPU and memory
ReadyNode drive listLimited drives to listed modelsDevice rules: exclusive, unpartitioned NVMe, 4 KB block size, PCIe 3.0 minimum with 4.0 or newer strongly recommended
ReadyNode certificationOne certified server for vSANServers: Red Hat hardware certification, owned by Red Hat and the server vendor. Storage software: the simplyblock Operator and CSI driver listing in the Red Hat Ecosystem Catalog, owned by simplyblock
ReadyNode network guidanceSet the network for the profileRedundant storage paths, at least 10 Gbit/s per storage node

The resilience row is plain arithmetic once you pick a scheme. The simplyblock erasure coding scheme table gives the overhead and the minimum node count for each:

  • 4+1 adds 25 percent at one failure tolerated (FTT 1) and needs at least six storage nodes.
  • 2+1 adds 50 percent at FTT 1 and needs at least four.
  • 4+2 adds 50 percent at FTT 2 and needs at least eight.
  • 1+1 and 2+2 add 100 percent, at FTT 1 with three nodes and at FTT 2 with six.

So 100 TiB of usable data needs 125 TiB of raw capacity at 4+1 and 150 TiB at 4+2, before any operating reserve. The reserve and the growth forecast are in VMware capacity planning after the exit. Rack layouts change which scheme fits; see rack failure domains and erasure coding.

Red Hat runs a bare metal hardware certification program for OpenShift servers. The Red Hat Ecosystem Catalog lists the simplyblock storage platform as certified software for OpenShift, covering its Operator and CSI driver integration. That software certification does not validate your exact mix of server, drives and firmware. Who owns drivers and firmware after the exit is in the compatibility matrix after a vSphere exit.

The per-node numbers a ReadyNode profile used to hide

On a hyperconverged worker, the VMs get what is left after the storage layer and the virtualization platform take their share. The simplyblock 26.3 hardware requirements say hyperconverged nodes must cover simplyblock and all other compute demand, including the Kubernetes worker itself and the operating system.

Work through each worker in this order:

  1. Storage vCPUs. For hyperconverged deployments, the docs recommend 15 to 20 percent of vCPUs, and never fewer than 8 vCPUs per socket. Very I/O-intensive applications need more. IOPS depend on the vCPUs a storage node gets. In Kubernetes, the CPU Manager and Topology Manager are used by default; isolating those cores from the operating system is opt-in and needs extra configuration.
  2. Storage nodes per host. By default, simplyblock deploys one storage node per NUMA socket, and only a socket with its own directly attached NVMe devices and NICs runs one. A two-socket worker with NVMe on both sockets therefore runs two storage nodes, each with its own storage vCPUs and memory. On a hyperconverged worker, the NUMA guidance notes that putting all NVMe devices on one socket and running a single storage node there saves CPU and memory. At 32 or more physical cores per storage node, the docs recommend turning hyperthreading off. The deployment detects the layout and proposes a configuration you can change.
  3. Storage memory. Each storage node needs 3 GiB fixed, plus 35 MiB per NVMe-oF subsystem, plus 0.5 GiB per TiB of storage capacity on the host. For the subsystem count, the docs recommend at least three per 10 Gbit/s of dedicated network bandwidth and one more per vCPU above eight, taking the lower of the two, with a hard limit of 500 per node. As a worked example of that formula (our arithmetic, not a documented case), a host with one storage node, 20 TiB of capacity, 20 Gbit/s of dedicated bandwidth and 16 storage vCPUs gets six subsystems and needs 13 GiB plus 210 MiB.
  4. Platform overhead. The OKD 4.22 virtualization requirements add about 360 MiB of memory to each worker node, plus about 2 cores on each worker that hosts VMs. Each VM adds about 218 MiB, plus 8 MiB per vCPU, 16 MiB per virtual graphics device and 0.002 times its requested memory. Add 1 GiB for each GPU or SR-IOV network device, 53 MiB when TPM is enabled and 256 MiB when SEV is enabled. Infrastructure nodes need 4 more cores and 2,179 MiB of memory in total, plus about 150 MiB each. These figures come from Red Hat’s test setup and vary by environment.
  5. Storage minimums. A storage node needs at least 8 vCPUs, 6 GB of RAM, two dedicated NVMe devices, 10 Gbit/s of network and 10 GB of free boot disk, all exclusive to simplyblock. These are reserved for the storage node alone, on top of what the VMs, the platform and the operating system need, so they do not compare with a ReadyNode host baseline. One NVMe device works for tests but is not approved for production.
Socket 1
VMs and containers
Storage node
vCPUs and memory
simplyblock
Own NVMe and NICs
Socket 2
VMs and containers
Storage node
vCPUs and memory
simplyblock
Own NVMe and NICs
Whole worker
OpenShift Virtualization overhead
Worker and operating system
WorkloadsReserved
Figure 1: what a two-socket worker with NVMe on both sockets reserves

The simplyblock control plane needs sizing too. It runs as three replicas on three nodes, either workers or Kubernetes control plane nodes, and each replica needs 4 vCPUs, 8 GiB of RAM and about 25 GiB of disk. That size manages up to three storage nodes and 18,000 objects, of which up to half can be logical volumes. Each storage node above three adds 1 vCPU, 2 GB of RAM, 5 GB of disk and 5 GB of backup space to the management nodes. The Management API runs as a DaemonSet on all workers unless a taint keeps it off, and the docs highly recommend an S3 bucket of at least 50 GB for control plane database backups.

Does storage scale with compute? Choosing a node layout

Storage scales with compute only when every worker is also a storage node. On OpenShift, simplyblock also runs on a subset of labelled workers or as a separate storage cluster, so you decide how the two grow.

The simplyblock hyperconverged and disaggregated concept pages describe the trade-off. In a hyperconverged cluster, added nodes bring both compute and storage capacity. In a disaggregated cluster, compute and storage scale separately and have separate lifecycles. The cost is the loss of data locality and a minimum scale for the storage cluster. The OpenShift installation guide adds the middle option: not every worker has to host storage, and node labels pick the ones that do.

Hyperconverged
VMs and containers
Every worker
Storage node and local NVMe
Every worker
Labelled storage workers
VMs and containers
Any worker
Storage node and local NVMe
Labelled workers
Separate storage cluster
VMs and containers
Compute cluster
Storage nodes and NVMe
Storage cluster
ComputeStorage
Figure 2: where storage runs in each node layout

Pick the layout by how your capacity and compute grow:

  • Choose hyperconverged when capacity and compute grow together and you want one server type. Every worker then carries the reservations from the previous section.
  • Choose labelled storage workers when only some servers have NVMe, or when you want the storage node reservation on fewer workers.
  • Choose a separate storage cluster when capacity or I/O grows faster than compute, or when storage maintenance must not follow worker upgrades and reboots.

Growth happens online. The expansion guide adds nodes through a StorageNodeSet with spec.expand: true, one expansion at a time, followed by a low-priority rebalance. An expansion is refused unless the cluster is active, every storage node is online and no migration, node restart or backup task is open. The rebalance that follows still runs on the data path, so start an expansion while the cluster is not fully utilized. With failure domains, the domains must hold the same number of hosts at activation, may then differ by at most one host, and each must keep at least two hosts once the cluster holds data. Buy in units that keep them balanced.

What has no replacement, and how to close each gap

A ReadyNode came with one certified unit, a published performance estimate per profile and one list to check before the next order.

  1. One certified unit. A ReadyNode was certified as a whole for vSAN. Now the server, the storage software and your drive and firmware mix are separate checks. Write your validated bill of materials down and keep it with the cluster.
  2. A performance estimate per profile. The November 2025 ReadyNode guidance lists an estimated IOPS figure for each base configuration. For your own hardware, measure it. Run the workload on the scheme and node layout you picked, then test a node failure as described in storage rebuild after a node failure.
  3. One list for future purchases. The simplyblock docs recommend separate clusters for different types of NVMe, network or compute hardware. Decide the hardware profile of each cluster before the first order, so later purchases match it.

Questions and Answers

Do I need a Broadcom account to use the vSAN Sizer?

Yes. The reverse-sizer steps in Broadcom KB 314302 begin with a sign-in at vcf.broadcom.com/tools/vsansizer/ and list a Broadcom account as required. They then open the Quick Sizer, the reverse sizer, from the vSAN ReadyNode Sizer page.

Can I reuse vSAN ReadyNode drives for simplyblock?

Often, if they meet the simplyblock 26.3 requirements. The NVMe devices must be exclusive to simplyblock, unpartitioned and unmounted, with a 4 KB native block size or 512-byte devices with 4 KB write atomicity. Deployment low-level formats the devices and destroys the data on them, so migrate the data off first. The docs recommend NVMe devices between 1.9 TiB and 7.68 TiB; larger devices work but give less performance per TiB and rebalance more slowly.

Can I mix drive sizes in one simplyblock cluster?

You can, but the simplyblock docs do not recommend it: they advise devices of the same size with a similar performance profile per TB in each cluster. You also cannot mix NVMe mode with Linux block-device mode, which is experimental in 26.3, within one cluster, and the mode cannot change after creation.

You may also like:

NVMe Storage Cost Optimization in 2026: Erasure Coding, Thin Provisioning, and Compute Efficiency
NVMe Storage Cost Optimization in 2026: Erasure Coding, Thin Provisioning, and Compute Efficiency

NVMe drives deliver the performance Kubernetes stateful workloads need, but triple replication and thick provisioning multiply their cost fast. Here is a practical breakdown of erasure coding economics, thin provisioning, and how sub-millisecond latency reduces compute waste.

Replacing vSAN Storage When Moving to OpenShift or Kubernetes
Replacing vSAN Storage When Moving to OpenShift or Kubernetes

Most VMware migration guides focus on the compute layer — but vSAN is the storage layer, and it does not migrate. Here is what platform teams need to plan when replacing vSAN as part of an OpenShift or Kubernetes transition.

Simplyblock Replaces Your VMware and Database Architecture
Simplyblock Replaces Your VMware and Database Architecture

The VMware + database stack was never designed for modern workloads. Here's how simplyblock and PostgreSQL replace it with a decoupled, API-driven, Kubernetes-native data architecture.